Installation
Section 2 (continued)

2.2 Controls and Displays

Familiarize yourself with the controls and
displays prior to installing or testing the
dehydrator.

2.2.1 Dehyrdrator Controls/Displays

A) Pressure Gauge Indicates dehyrdrator output
pressure in psi and kPa.
B) ON/OFF Controls compressor and
sensors. Light indicates
switch is ON.
C) Circuit Breaker White tab indicates overload.
Push to reset.
Desiccant Color Normal blue color changes
to pink as it is used. Pink at
the right side of the viewing
window indicates 5% capacity
remaining and time for change.

2.2.2 Distribution Panel Controls

ON/OFF Output port control valves
for MR-050 and DP-4-001.

2.3 Installing the Dehydrator

MR-050 Series dehydrators are designed for
low vibration and low noise and can safely be
placed in an existing equipment rack or cabinet.
They are also suitable for wall or shelf
mounting. Only minimal tools and hardware are
required.

2.3.1 Dehyrdrator Rack/Cabinet Mounting

Hardware is included for mounting directly into
a standard 19" (483 mm) equipment rack. Route
electrical wiring and air line through the holes
in the rear and/or side of the chassis.

2.3.2 Dehyrdrator Wall Mounting

Two keyed slots on the rear of the chassis are
provided for wall mounting. Use No. 10 or 12
panhead, wood screws, or 3/16" lag screws
long enough to properly secure the unit.

Masonry wall (concrete or cinder block), use
concrete screws or screws with lead anchors or
anchor bolts.

Frame wall. Use a plywood backer, 3/4" thick x
24" W (or wider) x 18" H. Securely attach the
backer to two wall studs with the mounting
screws. Route electrical wiring and air tubing
through the hole in the right side of the
chassis. Wall mounting hardware is not
included.